Merge Engine Scheduling

This preferences page defines how different instances and speed units are attributed to different jobs when creating Content Items (Print Content, as well as Web and Email output generation). For information on the terminology and some performance tips, see Performance Considerations. Note that in this dialog, the use of the word "Engine" is synonymous to both "Instance" and "Speed Unit" since a single Speed Unit can be used for each Engine.

Email and Web output is generated only with the Merge Engine and thus their output speed is limited through this engine. However, the output speed of Print jobs is limited through the Weaver Engine, so when Print Content is generated through the Merge Engine, its speed is not limited. Additionally, you may launch up to 256 engines for Print Content generation, but Email and Web may only use the number of engines permitted by your license.

  • Use one internal engine: Check to limit to a single instance of the server. Useful for computers that run below the recommended System requirements, or demo machines.
  • Total Engines Available: Read-only box indicating the current number of engines that are active or available.
  • Engines Launched: Enter the total number of Merge Engines desired on this server. When changing the number of engines, it is necessary to save this dialog (Apply) and restart the OLConnect_Server service to actually apply the changes.
  • Reserved Count: Read-only box indicating the total number of "Reserved" engines, as set in the Speed unit reservations area below.
  • Restart After (mins): Due to a currently unfixable memory leak in some libraries used by PlanetPress Connect, it is necessary to restart our engines after a certain amount of time. The default is generally sufficient for all our clients. Only change on the advice of a technical support agent.
  • Parallel speed units per job: This area determines how many engines (speed units) are used for each job that runs through it. In short, if any specific type of job has more than one parallel speed unit assigned to it, that many engines will be used to run each of its jobs. This is in fact a multiplier of speed, however it is a divider of the number of jobs that can be run simultaneously. You cannot attribute more parallel speed units than what you have available for any specific type of job, and you require at least that number of floating speed units, or reservations, for the required parallel speed units required.
  • Speed unit reservations:This area is used to reserve speed units specifically for certain types of jobs. Reserved speed units cannot be used by any other type of job.

    • Floating: Read-only box indicating the number of floating speed units that can be used for any type of job. This number is equal to the Total Engines Available - Reservations. For example if 6 engines are launched and 4 are reserved for small jobs, 2 will be Floating.
    • Small job speed unit reservations: Enter a number of speed units reserved for small print jobs.
    • Medium job speed unit reservations: Enter a number of speed units reserved for medium print jobs.
    • Large job speed unit reservations: Enter a number of speed units reserved for large print jobs.
    • Email speed unit reservations: Enter a number of speed units reserved for Email jobs.
    • Web speed unit reservations: Enter a number of speed units reserved for Web jobs.
  • Maximum speed units: This area defines the maximum possible speed units used for any specific job type. The limit needs to be at least the number of reservations or parallel speed units, whichever is lowest.
    • Small job limit: Enter the maximum number of speed units that can run small print jobs.
    • Medium job limit: Enter the maximum number of speed units that can run medium print jobs.
    • Large job limit: Enter the maximum number of speed units that can run large print jobs.
    • Email limit: Enter the maximum number of speed units that can run Email jobs.
    • Maximum Email limit in license: Read-only box indicating the maximum number of speed units useable for Email content creation.
    • Web limit: Enter the maximum number of speed units that can run Web jobs.
    • Maximum Web limit in license: Read-only box indicating the maximum number of speed units useable for Web content creation.
 