Automatic Restart Settings
It is considered good management to restart the Connect Engines periodically. This dialog provides the controls for scheduling Connect Engines restarts.
- Time Limit checkbox: This enables engine restarts to be scheduled to occur either after a specified period of time, or within a daily time window.
This means daily Engine restarts can be scheduled to run outside of production hours. - Rolling restart checkbox: This sets the engines restarts to occur in a "rolling" fashion, whereby each engine is stopped and restarted individually, one after the other.
Each engine is only stopped when the previously restarted engine is once again ready to start processing. - Restart method: Chose between restarting after a specified number of minutes (Restart after interval) or within a daily time window (Daily restart in period).
- Restart after (minutes): Only available if Restart after interval selected.
Specify the amount of minutes that the restarts are to occur after. - Daily restart period begin: Only available if Daily restart in period selected.
Enter the daily start time for the time window in which automatic restarts will be scheduled to occur. - Daily restart period end: Only available if Daily restart in period selected.
The end of the daily time window in which the automatic restarts are scheduled to occur. - Memory limit group: Enter the memory limit for individual Engines. If any of the memory limits are exceeded, an automatic restart of those Engines will be triggered.
- Data Mapper Engine (MB): Enter the memory limit for Data Mapper Engine.
- Merge Engine (MB): Enter the memory limit for Merge Engine.
- Weaver Engine (MB): Enter the memory limit for Weaver (Output) Engine.